Enterprise 64/128 Development
Klive assembles machine code for the Enterprise 64 and 128, runs it in the emulated machine, debugs
it at the source level, and exports it as a .com file, the form EXOS loads and starts programs in.
Applies to: Enterprise 128, Enterprise 64
Quick Start
Create a project for the Enterprise and its code/code.kz80.asm is a program that opens a page of
text through EXOS and writes into it:
; An Enterprise 64/128 machine-code program: an EXOS "$$APP". Run (or Debug) boots IS-BASIC and types
; LOAD "FILE:KLIVE.COM"; EXOS loads the program at $0100 and starts it there. Export writes the same
; program as a .com file, which LOAD "FILE:name.COM" runs.
;
; EXOS starts the program on its own system stack, so the program sets its stack first. EXOS has
; closed every channel: the program opens a VIDEO: page, shows it and prints into it.
.model ENTERPRISE
Start:
di
ld sp,$3FFF ; a stack of the program's own, at the top of page 0
ei
ld hl,VideoSetup ; the page's mode, colours and size: EXOS variables 22-25
ld c,22
SetVar:
ld d,(hl)
ld b,1 ; write...
push hl
push bc
rst $30 ; EXOS call...
.defb 16 ; ...16: set an EXOS variable (C: its number, D: the value)
pop bc
pop hl
inc hl
inc c
ld a,c
cp 26
jr nz,SetVar
ld a,1 ; channel 1...
ld de,VideoName
rst $30
.defb 1 ; ...1: open the channel to VIDEO:
ld a,1
ld bc,$0101 ; B=1: display the page (@@DISP), C=1: from its first row
ld de,$1801 ; D=24 rows, E=at screen row 1
rst $30
.defb 11 ; ...11: the channel's special function
ld a,1
ld de,Message
ld bc,MessageEnd-Message
rst $30
.defb 8 ; ...8: write the text to the channel
Done:
jr Done ; stay here; a reset ends it
; MODE_VID 0 (hardware text), COLR_VID 0 (two colours), X_SIZ_VID 40 characters, Y_SIZ_VID 24 rows
VideoSetup:
.defb 0, 0, 40, 24
VideoName:
.defb 6
.defm "VIDEO:"
; CR LF starts a new line
Message:
.defm "Welcome to Klive IDE"
.defb 13, 10
.defm "on the Enterprise"
.defb 13, 10
MessageEnd:Press Run: the screen clears and shows the two lines of welcome.
The model
.model ENTERPRISE (any case) assembles for the Enterprise 64 and 128; a source with no .model
takes the running machine’s. #ifmod ENTERPRISE and #ifnmod ENTERPRISE pick Enterprise-only parts.
Code with no .org goes to $0100. .bank is not available: paging is the program’s own business
(ports $B0-$B3), or EXOS’s.
How the code gets into the machine
Run and Debug load the program the way EXOS loads any program, through Klive’s FILE: device:
- Klive switches the machine on and, when the ENTERPRISE banner waits for a key, presses one.
- At IS-BASIC’s
okit typesLOAD "FILE:KLIVE.COM". TheFILE:device hands EXOS the assembled program from memory; nothing is written into yourFILE:folder. - EXOS loads the program at $0100, pages RAM in at $0000-$BFFF, and starts it at $0100.
Debug works the same way; the debugger stops at your breakpoints once EXOS has started the code. Run
needs the FILE: device (Machine › FILE: Device (Host Folder)); with the device off, Run says so
and does not start.
EXOS always starts a program at $0100. When the .ent address is elsewhere and $0100-$0102 hold no
code, Klive puts a JP to the entry there; when other code is at $0100, Run and Export refuse the
program and say why.
Rules of the machine
- Where code goes. From $0100 to $BFFF. Below $0100 is EXOS’s page-zero area, and while a program
runs page 3 ($C000-$FFFF) holds EXOS’s system segment. The assembler warns about code outside the
range, and Run and Export refuse it:
- Z0386: “Code at $xxxx is below $0100: on the Enterprise, EXOS loads a program at $0100 and keeps its own data below it.”
- Z0387: “Code at $xxxx is too high for the Enterprise: a program may reach $BFFF; from $C000 up is EXOS’s system segment.”
- The stack. EXOS starts a program on its own system stack, so the program must load SP before
interrupts can come: the first interrupt on EXOS’s stack lands the CPU in EXOS. Do it as the
template does, with
DI,LD SP,...,EIas the first three instructions. - Channels. EXOS closes every channel before it starts a program. To show text, open a
VIDEO:page and display it, as the template does: anEDITOR:channel alone shows nothing until its page is displayed. - Interrupts. NICK’s video interrupt and DAVE’s 1 Hz timer run EXOS’s interrupt handler, which keeps the clock, the keyboard and the sound going. Code that disables interrupts should enable them again.
EXOS calls
RST $30 calls EXOS, with the function’s code in the byte after it:
ld a,1 ; the channel
ld de,Message ; the text
ld bc,5 ; its length
rst $30
.defb 8 ; EXOS 8: write a block to the channelThe call returns after that byte, with the status in A (0 for success). The function codes are 0-11 (the channel functions: open, create, close, destroy, read and write a character or a block, status, special functions) and 16-34 (the system functions: EXOS variables, channel redirection, segments, ROM extensions, modules, the time and the date). Codes 12-15 and those above 34 are not functions.
The disassembler lists the byte after RST $30 as data with the function’s name, for example
.defb $08 (EXOS 8: Write block), and Step Over steps over the call and its byte.
Exporting
Export (or expc <file>) writes a .com file, with -f com or by default: EXOS’s 16-byte module
header for a new application (module type 5, the length of the code) and the code from $0100. Copy it
into the FILE: folder and LOAD "FILE:NAME.COM" loads and starts it, on Klive or on any Enterprise
that can read the file. The file always starts itself, so the export has no loader option. -f hex
writes Intel HEX instead.
Testing
Z80 unit tests run on the Enterprise: the runner boots the machine to
IS-BASIC’s prompt and calls each test. klive run runs an Enterprise project.